Results 1 to 10 of 16
Thread: Variable Capacitance Testing
Threaded View
-
09-22-2014, 01:40 AM #2
- Join Date
- Jun 2014
- Location
- Burnley, UK
- Posts
- 1,662
Why use capacitance when resistance will probably give you better, more repeatable and stable results?
If you use resistance and a Wheatstone bridge with one fully submerged for a reference and one that gets progressively covered as the depth increases then you have it sorted and stable. Capacitance will vary with location and even your proximity but resistance will not.
Printer will print perfect...