Results 1 to 3 of 3
-
07-26-2018, 01:38 PM #1
- Join Date
- Jul 2018
- Posts
- 1
RAMPS PLUS 2 and E1 socket problem (K200 Delta, but related to the PCB , not printer)
Hi
Total 3D printing newbie here, apoloies in advance if my terminology is wrong.
I have a dual head K200 delta printer with a heated bed which I put together 8 months ago, but gave up due to frustration of the following error in Repetier:
temp sensor defect marked defect
Error:Printer set into dry run mode until restart!
I've tried again today, and all 3 thermistors (and the spare) work fine, but socket E1 on the BT7200 V1.8.26 RAMPS PLUS 2 is giving me -20oC readings no matter which thermistor I put in.
Even though I?ve tried to tell it there?s only 1 extruder (in Printer Settings), the display right at the bottom of Repetier still thinks there?s 2.
Today I've emailed the seller and the company I bought it *through*, to see if they can help.
In the meantime - is there any way to make Repetier believe that I only have 1 extruder, or change things so that I can use the heated bed socket for the other extruder instead and just try to make due without the heatbed for now?
Hope you can help.
-
07-27-2018, 07:51 PM #2
- Join Date
- Jul 2018
- Posts
- 10
TC1967UK
You could try and follow the wires back and disconnect it from both ends. Then select in your slicing software as extruder1. Let me know how it goes.
John
-
08-02-2018, 06:23 AM #3
just plug the one extruder in.
So extruder cable and thermistor. for drive 0.
Basically what john says but usually a single extruder is extruder 0, extruder 1 is the second extruder.
Ender 3v2 poor printing quality