    The 11A input will also need 12V going to it in order for the heat bed output to have any voltage to drive the SSR. You won't need much current. It's fine to run some light gauge jumpers from the other 12V input over to the 11A input.

    EDIT: The power input for the heat bed is kept separate in order to support those people who run a different voltage heat bed, like 24V.
    Last edited by printbus; 02-25-2016 at 12:01 PM.