According to the spec sheet for the Omron G8QN, the electrical contacts are rated for at least 100,000 operations. Assuming around a 5 second time base for the PID routine*, then the relay would be good for at least around 70 hours of operation. I guess I should have a plan for replacing mine at some point ;-)
Seems like a power MOSFET that uses the bed as a heat sink might be worth exploring?
Jim
* This was not immediately obvious to me in the Marlin code. Does anyone know what the default value is, and where the code is located?Last edited by JimG; 12-05-2014 at 05:44 PM. Reason: fixed estimate duration