Ryan,<br>
<br>
I have sample gcode commands explained in depth at <br>
http://hyrel3d.net/forum/viewforum.php?f=16<br>- where I can create an account for you if you like. PM me here or email me.<br>
<br>
To summarize:<br>
<br>
1. All commands are sent via gcode.<br>
2. All variables are persistent unless/until a new value is given;<em> this includes which head(s) you are addressing.<br>
</em>3. Data loaded from the heads themselves to the Repetrel software are sent to the motion controller FIRST, then the gcode is sent - so gcode settings will overwrite (for the duration of the print) the head settings.<br>
<br>
So:<div style="margin-left:40px"><strong>M221 S1.1</strong> will change the flow rate multiplier from whatever it was previously (based on path width, layer thickness, length of printing move and print speed - TIMES this multiplier) to 1.1, or a 10% greater flow - <em><strong>ON THE HEAD LAST ADDRESSED with a T variable.</strong></em><br>
<br>
<strong>M221 S1.1 T12</strong> will do the same for the second head only (yoke 1, position 2).<br>
<br>
<strong>M221 S1.1 T10</strong> will broadcast this new flow rate multiplier to every head on yoke 1 (the only yoke on current models).</div><br>
Also:<div style="margin-left:40px"><strong>M104 S220 T10 </strong>(or <strong>M104 T10 S220 </strong>- the order of the variables does not matter) will set the temperature for all heads to 220C.<br>
<br>
<strong>M109 S220</strong> (set temp to 220 and wait for head to reach 220) will only be applicable to the last head addressed with a T value; I don't recommend waiting for ALL heads (since the prior command in your example used a T10) unless you are, in fact, printing with all four heads, as missing heads will never report that they have reached this temperature. Rather, <strong>M109 S220 T12</strong> (or whatever) should be used.</div><br>
Please let me know if this did not satisfactorily answer your questions, or if you have others.