Oh you're talking about the G29 using 3 point. I set the points properly, but then it move to the first point, doesn't even probe it and just stops. Right now trying out UBL but it didn't work either. Here is the weird thing. Here is what the mesh said after the G29 UBL (Unified Bed Leveling):
17:13:10.568 : . . . 1.694 0.402 0.219 0.327 0.720 . . .
17:13:10.568 :
17:13:10.738 : . . 0.524 0.053 0.032 0.099 0.094 0.190 0.334 . .
17:13:10.738 :
17:13:10.909 : . 0.120 0.001 0.010 0.012 0.010 0.062 0.080 0.062 0.108 .
17:13:10.909 :
17:13:11.079 : . -0.003 -0.002 0.034 0.035 0.013 0.035 0.010 -0.036 -0.036 .
17:13:11.080 :
17:13:11.277 : 0.081 0.025 0.034 0.036 0.075 0.007 -0.015 -0.015 [-0.015] .
17:13:11.277 :
17:13:11.447 : . 0.140 0.109 0.061 0.082 0.095 0.059 0.035 0.058 -0.010 .
17:13:11.447 :
17:13:11.618 : . 0.179 0.119 0.075 0.077 0.061 0.073 0.086 0.067 -0.007 .
17:13:11.618 :
17:13:11.789 : . . 0.100 0.054 0.060 0.045 0.168 0.115 0.067 . .
17:13:11.789 :
17:13:11.959 : . . . . . -0.018 . . . . .
17:13:11.983 : (-114,-114)


Something is wrong on the top left of the bed, a whole 1mm difference?

I know I'm asking this again, but maybe I should print out those manual leveling knobs and try to level that way?