    Using a calibrated digital thermometer, attached to nozzles,
    we found that right-nozzle averaged about 14 C Hotter than temp displayed at printer
    and left-nozzle averaged about 6 C Hotter than displayed.

    So, we lowered Temp setting in Host/slicer software by those amounts
    and printed objects were much better.

    Not sure if error is caused by Thermocouple-wires or the Motherboard circuit.
    Maybe someday I'll replace T-wires to determine if they cause it.

    Note: Bed-plate temp, on top of added glass, averaged about 12 C cooler than Indicated temp at display.
    The Fan cooling X & Y stepper-motors is probably cooling the glass.