20mm x 20mm test square is slighty off square
Got a small problem... my test 20mmx 20mm cube is comming out 20mm (x) by 19.7mm (y)
I thought it was belt tension so I re-did the belts but got the exact same result.
Can the offset be compensated for in firmware?
Is there a table I can change?
Running Sailfish latest on a CTC with Mightyboard.
Thanks
Ray
-
04-26-2016, 06:39 AM #2
- Join Date
- Dec 2015
- Posts
- 80
Been told, but not doen this myself yet, that you can go into the Sailfish RepG install folder, and then go into the machines folder and there you will see a list of xml files for different machines.
Open replicator-sailfish.xml with a text editor and then find your new steps/mm and simply replace the old values with the new.
Then reinstall the firmware.
-
04-26-2016, 11:38 AM #3
- Join Date
- Apr 2016
- Posts
- 28
Nice one, ill give it a try later.
My prints are 2% smaller on the y axis, so I assume one just needs to modify the step/MM by 2%.
I let you know how it goes.
Ray
-
04-26-2016, 06:33 PM #4
- Join Date
- Dec 2015
- Posts
- 80
I would do it this way
http://reprage.com/post/46062359808/...our-3d-printer
This method also saves on wasting filament on making a calibration print each time.
I think the best way would be to measure and change the steps a couple of times and then print a calibration prints to make sure.
-
04-27-2016, 04:42 PM #5
- Join Date
- Apr 2016
- Posts
- 28
Looks like a good method, thanks for the link. I'll try this also.
Printer will print perfect...